8 Inch Color Screen Multi Parameter Patient Monitor With Optional Four On-board Devices
Feature
1 | The new high-precision module and the new digital blood oxygen technology make the measurement more comprehensive and accurate. |
2 | High-brightness and high-resolution 8-inch color TFT LCD display, exquisite design, weight only 1.5KG. |
3 | With ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis. |
4 | The whole process, full parameter trend chart data, ECG waveform storage and playback, and power-down save function. |
5 | Rotary shuttle operation mode, Chinese and English logo buttons, easy to learn and use, simple and intuitive operation. |
6 | Standards, large fonts, full leads, and trend charts coexist for easy viewing from multiple angles. |
7 | Built-in removable lithium battery, AC and DC dual purpose, light, energy-saving and environmentally friendly. |
8 | Suitable for adults, children, newborns; suitable for bedside monitoring, ICU/CCU, operating room, emergency center, family monitoring, etc. in various hospital departments. |
9 | Optional four kinds of vehicle-mounted devices, suitable for various transportation vehicle-mounted mobile environments. |
Standard Configuration
1 | PM-9000 8 Inch multi-parameter monitor host | 1 unit |
2 | Built-in rechargeable lithium battery | 1 unit |
3 | Standard five-lead ECG lead connection cable | 1 set |
4 | Standard adult blood pressure cuff | 1 set |
5 | Adult blood oxygen probe | 1 set |
6 | Temperature probe | 1 set |
7 | Power plug cord | 1 set |
8 | Ground wire | 1 set |
9 | User's manual | 1 set |
Specification
1 | ECG | Lead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display Gain selection: ×1, ×2, ×0.25, ×0.5 four gears Frequency: 0.5Hz—100Hz Common mode signal rejection: greater than 70dB Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files Heart rate accuracy: ±5 beats/minute Calibration signal: 1mV (peak value, accuracy ±3%) ST segment detection: measuring range (-2.0mV---+2.0mV) Use standard: in line with ANSI/AMI EC13-2002 standard Response time: 1S Alarm mode: sound and light alarm Heart rate alarm preset range: (exceed the preset value alarm) The upper limit is adjustable between 1-255 times/minute The lower limit is adjustable between 0-254 times/minute |
2 | NIBP | Technology: Oscillographic Method Measurement method: reverse measurement data is more accurate Unit of measurement: mmHg/Kpa Overvoltage protection: double safety protection One measurement time: less than 45S Pressure range in cuff: 0-250mmHg Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value Initial inflation of cuff: 180mmHg (120mmHg for children) Cuff subsequent inflation: original systolic blood pressure + 30mmHg Blood pressure measurement range and error: Systolic blood pressure 60 mmHg~250 mmHg Average pressure 45 mmHg~235 mmHg Diastolic blood pressure 40 mmHg~220 mmHg Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater Response time: 1S Alarm mode: sound and light alarm Alarm prediction range and error: (Alarm when exceeding the preset value) Systolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg ~255 mmHg Diastolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg~254 mmHg Alarm error: ±1 mmHg Use standard: in line with ANSI/AAMI SP10-2002 standard |
3 | SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 beats/min Response time: 1S Alarm mode: sound and light alarm Alarm range and error: (Alarm exceeding the preset value) Upper limit 1%~100% Lower limit 0%~99% |
4 | TEMP | Technology: Highly sensitive thermistor probe Body temperature measurement range: 20℃-- 45℃ Resolution: 0.1% Body temperature accuracy: ±1℃ Response time: 1S Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 20.1℃-- 45.5℃ The lower limit is adjustable between 20℃ and 45.4℃ Alarm error: ±1℃ |
5 | RESP | Respiration rate range: 0-60 times/min Accuracy: ±1rpm Response time: 1S Gain options: ×1, ×2, ×4, ×0.5 four gears Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 10-100 times/minute The upper limit is adjustable between 0-99 times/minute Alarm error: ±1rpm |
6 | Printer(Optonal) | Specifications: Dual-channel thermal array recorder Printing method: real-time or event trigger recording waveform, text Resolution: Horizontal: 400dpi / Vertical: 800dpi Note: Date (year/month/day)/time (24 hours) Optional wall bracket, mobile bracket, backpack |
7 | System | Display: 8 inch TFT true color LCD display Battery (optional): LeadAcid fully sealed maintenance-free battery |
Wuxi Biomedical Technology Co., Ltd.
Wuxi Biomedical Technology is a professional manufacturer of
infrared vein finder, digital otoscope, ultrasound scanner, color
doppler and digital electronic colposcope. Now we are trying
to expand product field to ECG, Patient Monitor, Oxygen
Concentrator and infusion pump and so on.
With a wide range, good quality, reasonable prices and stylish
designs, our products are extensively used in medical field.
Our products are widely recognized and trusted by users and can
meet continuously changing economic and social needs. Because we
have own R&D capabilities to develop innovative medical
devices. Sophisticated management and assessment ensure good
reputation and quality.
We welcome new and old customers from all walks of life to contact
us for future business relationships and mutual success! We
are trying our best to offer professional after-sale service and
promise you buying with satisfaction, using at ease.