DPS series distributed power system
Performance characteristics
- Intelligent detection, battery type optional, output shunt timing
control
Intelligent detection of fan and capacitor running time
4 output shunts support timing control function
Battery type: lead-acid battery, lithium iron battery, ternary
lithium battery and custom battery type
- Reliable, intelligent and fast deployment
Modular design, rapid deployment on demand;
Simplify data center planning and design;
Compatible with T2/T3/T4 level in the same data center;
Intelligent detection of running time of fans and capacitors;
Dual 220VAC input, dual 220VAC output, can intelligently detect the
power of other equipment (optional).
- Effective use of space and load-bearing
The weight of the equipment is equivalent to that of the server,
and the weight bearing only needs 500Kg/m2;
The deployment does not require independent distributed power
system space and battery room, and the number of effective cabinets
has increased by more than 40%;
☆Energy saving and emission reduction, cabinet-level energy
management effectively combined with cloud computing
High efficiency power supply module, the efficiency of the whole
series of products is as high as 94%;
Full lithium battery backup system, discharge efficiency up to more
than 97%, life span up to 10 years;
Each output can be selected for time-sharing control. With the
energy management system, it can achieve cabinet-level energy
management and coordinate with cloud computing for scheduling;
☆Power supply host, modular design of lithium iron battery, hot
swappable, easy installation and maintenance
The product is designed and produced in a modular manner. The power
supply host and the iron-lithium battery are independent modules.
They support hot swapping while ensuring that the power equipment
does not lose power; small size, light weight, and can be completed
by one person.
More convenient installation and simple maintenance
Reasonable design of heat dissipation and airflow control, good
control of battery temperature;
The front part of the product is designed with heat dissipation
holes and air ducts for the power supply heating device and the
lithium battery, which can accurately control the temperature of
the power supply and the lithium iron battery;
☆Conducive to the user’s demand for low “PUE” value
The distributed power supply mode divides the power consumption of
the traditional large UPS into the cabinet and reduces the PUE
value.
Application field
Power supply application scenarios such as distributed data
centers, load-bearing limited data centers, phased deployment of
data centers, rapid deployment of data centers, and integrated
cabinets.
Power range: 1KVA – 10KVA (1PH/1PH)
Distribute Power System - DPS