
Description
● | Universal Relay Test Applications |
● | 10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics. |
● | Variable battery simulator, DC 0-350V, 140Watts max. |
● | Transient play back up to 3KHz |
● | Fully function KRT software testing modules |
● | Graphical test modules and templates for testing of various relays |
● | Quick relay testing facility in Manual mode |
● | Shot/Search/Check, Point & Click testing |
● | RIO/XRIO import & export facility |
● | Switch on to fault test(SOTF) |
● | Power system model for dynamic testing |
● | Online Vector display |
● | Automatic test results assume |
● | Automatic test report creation |
● | Inbuilt GPS sync end-to-end testing |
● | Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection |
● | 3-Years guarantee of free repair and life-long maintenance |
● | Lightweight, <19.5Kg |
● | Free software upgrade |
● | Energy meter calibration (Mechanical & Electronic meters) |
Items | ANSI® No. |
Distance protection relay | 21 |
Synchronising or synchronism-check relays | 25 |
Undervoltage relays | 27 |
Directional Power relays | 32 |
Undercurrent or underpower relays | 37 |
Negative sequence overcurrent relays | 46 |
Overcurrent/ground fault relays | 50 |
Inverse time overcurrent/ground fault relays | 51 |
Power factor relays | 55 |
Overvoltage relays | 59 |
Voltage or current balance relays | 60 |
Directional overcurrent relays | 67 |
Directional ground fault relays | 67N |
DC overcurrent relays | 76 |
Phase-angle measuring or out-of-step protection relays | 78 |
Automatic reclosing devices | 79 |
Frequency relays | 81 |
Motor overload protection relays | 86 |
Differential protection relays | 87 |
Directional voltage relays | 91 |
Voltage and power directional relays | 92 |
Tripping relays | 94 |
Voltage regulating relays | |
Overimpedance relays, Z> | |
Underimpedance relays, Z | |
Time-delay relays |
Specifications
Voltage Outputs | ||
Output Range & Power | 4×310 V ac (L-N) | 124 VA max each |
3×350 V dc (L-N) | 140 W max each | |
Accuracy | <0.02%Rd+0.005Rg Typ. <0.05%Rd+0.01Rg Guar. |
|
±10mV @ <5V dc ±0.5% @ ≥5V dc |
||
Voltage Range | Range I : 30V | |
Range II : 310V | ||
Automatic Range | ||
DC Offset | <10mV Typ./ <60mV Guar | |
Resolution | 1mV | |
Distortion | <0.015%Typ. / <0.05% Guar. | |
Current Outputs | ||
Output Range & Power | 6×35A ac (L-N) | 450 VA max each |
3×70A ac (2L-N) | 850 VA max each | |
1×100A ac (6L-N) | 1200 VA max | |
3×20A dc (L-N) | 300W max each | |
Accuracy | <0.03%Rd+0.02Rg Typ. <0.1%Rd+0.05Rg Guar. |
|
±5mA @ <1A dc ±0.5% @ ≥1A dc |
||
Current Range | Range I: 3A | |
Range II: 35A | ||
Automatic Range | ||
DC Offset | <3mA Typ./ <10mA Guar | |
Resolution | 1mA | |
Distortion | <0.025%Typ. / <0.07% Guar. | |
Frequency & Phase Angle | ||
Frequency Range | DC~1KHz, 3KHz transient | |
Frequency Accuracy | ±0.5ppm | |
Frequency Resolution | 0.001 Hz | |
Phase Range | -360°~360° | |
Phase Accuracy | <0.02° Typ. / <0.1° Guar. 50/60Hz | |
Phase Resolution | 0.001° | |
Aux. DC Voltage Source (Battery simulator) | ||
Range | 0~350V @ 140W max | |
Accuracy | 0.5%Rg Guar. | |
Binary Input | ||
Quantity | 8pairs | |
Type | wet/dry, up to 300Vdc max input | |
Time resolution | 10us | |
Sampling Rate | 10KHz | |
Debounce time | 0~25ms (Software Controlled) | |
Time range | Infinite | |
Time errors | ±1ms @ ≤1s, ±0.1% @ >1s | |
Galvanic isolation | Isolated each pairs | |
Binary Output (Relay Type) | ||
Quantity | 4pairs | |
Type | Potential free relay contacts, software controlled | |
Break Capacity AC | Vmax: 400Vac / Imax:8A / Pmax:2500VA | |
Break Capacity DC | Vmax: 300Vdc / Imax:5A / Pmax:150W | |
Binary Output (Semiconductor Type) | ||
Quantity | 4pairs | |
Type: | Open-collector, Combination type male | |
Break Capacity DC | 5~15Vdc / 5mA, 10mA max | |
Response time: | 100us | |
Synchronization | ||
Synchronization Mode | GPS, SMA type antenna connector | |
Power supply & Environment | ||
Nominal Input Voltage | 110V/220/230V ac, Appointed | |
Permissible Input Voltage | 85~264Vac, 125~350VDC, auto-protective | |
Nominal Frequency | 50/60Hz | |
Permissible Frequency | 45Hz~65Hz | |
Power Consumption | 1500 VA max | |
Connection Type | Standard AC socket 60320 | |
Operating Temperature | -10℃~55℃ | |
Storage Temperature | -20℃~70℃ | |
Humidity | <95%RH, non-condensing | |
Others | ||
PC Connection | RJ45 Ethernet, 10/100M | |
Grounding Terminal | 4mm banana socket | |
Weight | 19.5 Kg | |
Dimensions(W x D x H) | 360×450×140(mm) |
Advance
Energy Meter Calibration Hardware is ready, to be active | |
Sensor Usage | Mechanical meters / Electronic meters |
Sensor Output | High lever:>4.5V, Low level:<0.2V |
Pulse Input | 1 pulse input port, 5Vdc high level valid only. |
Pulse Range | 500KHz pulse input Max. |
Pulse Output | 1 Transistor output, Open-collector, 5Vdc/5mA |
Model | Current Outputs | Voltage Outputs | Optional Function |
K3066i | 6×35A @ 450VA max 3×70A @ 850VA max |
7×310V @ 90VA max | ● Energy Meter Cal. |
K3063i | 6×35A @ 450VA max 3×70A @ 850VA max |
4×310V @ 124VA max | ● Energy Meter Cal. |
K3030i | 3×35A @ 450VA max | 4×310V @ 124VA max | ● Energy Meter Cal. |
Kingsine Electric Automation Co., Ltd.
Who am I ?
Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, and Instrumentation. To date, Kingsine's products have been recognized by customers in more than 80 countries worldwide. We regularly participate in large-scale power and energy exhibitions worldwide, including in the United States, Italy, France, Poland, Australia, Dubai, Turkey, Brazil, Philippines, Malaysia, Indonesia, South Africa, Egypt, and other countries, and have received widespread acclaim.Our protection relay testing equipment is compatible with world-renowned relay protection devices such as ABB, SIEMENS, ALSTOM, MITSUBISHI, Schneider, AREVA, SEL, GE, and others. Kingsine Electric has also established a distribution network with partners in the Americas, Europe, Asia, the Middle East, and other countries to provide comprehensive services.
Kingsine is a core supplier to China's State Grid
The facts demonstrate that China's annual power generation has remained the world's number one, with a projected power generation of 840 billion kilowatt hours in 2022, compared to the United States' projected 430 billion kilowatt hours in the same year. China has built the world's most advanced power transmission system for DC current at 1100KV ultra-high voltage levels and more than 11,000 digitized substations based on the IEC61850 standard. China's power grid has the largest, most advanced, safest and most stable power system in the world. We are honored to be the core supplier for State Grid Corporation of China.
Where did I come from?
Kingsine Electric is located in Shenzhen, the "Innovation Capital of China". We have also established subsidiaries in Canada and Hong Kong. Shenzhen is a benchmark city for the development of China's high-tech industry and is home to leading Chinese companies in various industries. Many of China's top companies, including Huawei, the world's largest communication company; DJI, the world's largest commercial drone company; BYD, the world's largest electric vehicle company (which sold 1.86 million electric vehicles globally in 2022, surpassing Tesla's sales of 1.37 million); and Tencent, one of China's leading internet companies, are based in Shenzhen. Excellent enterprises can influence each other, and as the world's factory, Shenzhen has a highly advanced and comprehensive industrial chain, which provides a reliable guarantee for Kingsine Electric to develop, produce, and manufacture high-tech, high-quality, and reliable products.
Where am I going?
Philosophy
Adhering to the belief of novelty in technology and detail in service, and gradually establishing a global service and sales network with worldwide partners and distributors, Kingsine shall spare no effort to serve customers worldwide with innovative technology, reliable products, and quality online service, making electric testing easier across the world.
Business Principles
Kingsine's business principle is to create value for customers, which is reflected in three aspects.
Firstly, Kingsine uses advanced technology to create powerful product features that offer customers a great operating experience.
Secondly, Kingsine provides high-quality products and services at reasonable prices, ensuring that customers receive high value for their investment.
Thirdly, Kingsine emphasizes reliability and after-sales service, providing quality assurance through lean production and ensuring that products have over 15 years of service life and three years of warranty. Kingsine's after-sales maintenance principle is based on cost accounting, ensuring that after-sales service remains efficient and affordable.Based on our modular product design philosophy, and with the help of efficient video diagnostics, our target for after-sales maintenance service is to complete repairs within 20 days.